Step A: When water quality diminishes, deionizer needs to be refilled. Shut off water supply and remove tank head.
Step B: Empty resin into a waste container and rinse out tank. Dispose in accordance with federal, state, and local regulations.
Step C: Return distributor tube into the tank and place rubber cap over top of tube. Place funnel into top of the tank.
Step D: Slowly pour or scoop resin into tank. Shake or tap tank to get all of the resin bedded. Tank should be filled to approximately three inches from the top.
Step E: Remove funnel and rubber cap. Replace tank head. Make sure all o-rings are properly seated. Insure seating areas are free from foreign material; apply silicone lubricant to surface of o-rings.
Step F: Turn on water supply. The unit will now produce deionized water.